{"id":844,"date":"2021-01-01T16:58:33","date_gmt":"2021-01-01T15:58:33","guid":{"rendered":"https:\/\/preprod.prepasecu.fr\/?p=844"},"modified":"2023-07-03T15:51:43","modified_gmt":"2023-07-03T13:51:43","slug":"evacuation-du-public","status":"publish","type":"post","link":"https:\/\/prepasecu.fr\/ssiap-1\/cours\/la-securite-incendie\/evacuation-des-occupants","title":{"rendered":"\u00c9vacuation du public et des occupants"},"content":{"rendered":"\n<div id=\"paywall\" data-poool=\"90\" data-poool-mode=\"hide\">\n\n\n\n<h3 class=\"wp-block-heading\"><strong>D\u00e9finition<\/strong><\/h3>\n\n\n\n<p><strong>D\u00e9gagement<\/strong> : toute partie de la construction permettant le cheminement d\u2019\u00e9vacuation des occupants : porte, sortie, issue, circulation horizontale, zone de circulation, escalier, couloir, rampe, etc\u2026<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Les d\u00e9gagements r\u00e9glementaires :<\/strong><\/h3>\n\n\n\n<p><strong>D\u00e9gagement normal :<\/strong> d\u00e9gagement comptant dans le nombre minimal de d\u00e9gagement impos\u00e9s. Il peut \u00eatre utilis\u00e9 par le public lors de l\u2019exploitation de l\u2019\u00e9tablissement.<\/p>\n\n\n\n<p><strong>D\u00e9gagement de secours<\/strong> : d\u00e9gagement normal qui, pour des raisons d\u2019exploitation, ne sera utilis\u00e9 par le public qu\u2019en cas d\u2019\u00e9vacuation.<\/p>\n\n\n\n<p><strong>D\u00e9gagement accessoire :<\/strong> d\u00e9gagement qui peut \u00eatre exig\u00e9 en cas de mauvaise r\u00e9partition des d\u00e9gagements normaux.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>D\u00e9gagements suppl\u00e9mentaires :<\/strong><\/h3>\n\n\n\n<p><strong>D\u00e9gagement suppl\u00e9mentaire :<\/strong> d\u00e9gagement en surnombre par rapport aux d\u00e9gagements impos\u00e9s<strong>.<\/strong><\/p>\n\n\n\n<p><strong>Circulation principale :<\/strong> circulation horizontale assurant un cheminement direct vers les escaliers, sorties ou issues.<\/p>\n\n\n\n<p><strong>Circulation secondaire :<\/strong> circulation horizontale assurant un cheminement des personnes vers les circulations principales.<\/p>\n\n\n\n<p><strong>D\u00e9gagement prot\u00e9g\u00e9 :<\/strong> d\u00e9gagement dans lequel le public est \u00e0 l\u2019abri des flammes et de la fum\u00e9e :<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>soit d\u00e9gagement encloisonn\u00e9 :<\/strong> toutes les parois ont un degr\u00e9 de r\u00e9sistance au feu<\/li>\n\n\n\n<li><strong>soit d\u00e9gagement \u00e0 l\u2019air libre :<\/strong> la paroi donnant sur le vide de la fa\u00e7ade comporte en permanence, sur toute sa longueur, des vides au moins \u00e9gaux \u00e0 la moiti\u00e9 de la surface totale de cette paroi.<\/li>\n<\/ul>\n\n\n\n<p><strong>Porte \u00e0 ferme porte :<\/strong> porte \u00e9quip\u00e9e d\u2019un dispositif destin\u00e9 \u00e0 la ramener \u00e0 sa position de fermeture d\u00e8s qu\u2019elle en a \u00e9t\u00e9 \u00e9loign\u00e9e pour le passage des personnes ou pour le service.<\/p>\n\n\n\n<p><strong>Porte \u00e0 fermeture automatique :<\/strong> porte \u00e9quip\u00e9e d\u2019un ferme porte et d\u2019un dispositif qui peut la maintenir en position ou verte et la lib\u00e8re au moment du sinistre.<\/p>\n\n\n\n<p><strong>Escaliers prot\u00e9g\u00e9s \u00e0 l\u2019air libre :<\/strong> est consid\u00e9r\u00e9 comme \u00e0 l\u2019air libre un escalier dont une de sa fa\u00e7ade pr\u00e9sente une ouverture de 50%<\/p>\n\n\n\n<p><strong>Escaliers prot\u00e9g\u00e9s \u00e0 l\u2019abri des fum\u00e9es :<\/strong> est consid\u00e9r\u00e9 comme \u00e0 l\u2019abri des fum\u00e9es, un escalier dont l\u2019enveloppe pr\u00e9sente une r\u00e9sistance au feu, qui lui conf\u00e8re un isolement par rapport aux volumes contigus.<\/p>\n\n\n\n<p><strong>Espaces d\u2019attente s\u00e9curis\u00e9s : <\/strong>zone \u00e0 l\u2019abri des fum\u00e9es, des flammes et du rayonnement thermique : une personne quel que soit son handicap, doit pouvoir s\u2019y rendre et, si elle ne peut poursuivre son chemin, y attendre son \u00e9vacuation gr\u00e2ce \u00e0 une aide ext\u00e9rieure.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Conception&nbsp;:<\/strong><\/h3>\n\n\n\n<p>Les d\u00e9gagements doivent \u00eatre con\u00e7us pour permettre une \u00e9vacuation rapide et s\u00fbre de l\u2019ERP. Il est interdit en particulier, de placer une ou deux marches isol\u00e9es dans les circulations principales.<\/p>\n\n\n\n<p>A chaque sortie sur l\u2019ext\u00e9rieur ou sur un d\u00e9gagement prot\u00e9g\u00e9 correspond une circulation principale<\/p>\n\n\n\n<p><strong>Des circulations principales de 1,40m <\/strong>au moins relient les d\u00e9gagements entre eux. Toutefois, la largeur peut \u00eatre de 0,90 lorsque les d\u00e9gagements reli\u00e9s n\u2019offrent qu\u20191UP.<\/p>\n\n\n\n<p><strong>Les culs-de-sac :<\/strong> les portes des locaux accessibles au public donnant sur des d\u00e9gagements en cul-de-sac ne doivent pas \u00eatre \u00e0 plus de 10 m\u00e8tres du d\u00e9bouch\u00e9 de ce cul-de-sac.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"605\" height=\"295\" src=\"https:\/\/preprod.prepasecu.fr\/wp-content\/uploads\/2021\/01\/image-6.png\" alt=\"\" class=\"wp-image-846\" srcset=\"https:\/\/prepasecu.fr\/wp-content\/uploads\/2021\/01\/image-6.png 605w, https:\/\/prepasecu.fr\/wp-content\/uploads\/2021\/01\/image-6-300x146.png 300w\" sizes=\"(max-width: 605px) 100vw, 605px\" \/><figcaption class=\"wp-element-caption\">Exemple de culs de sac<\/figcaption><\/figure><\/div>\n\n\n<p>Le nombre et la largeur de chaque d\u00e9gagement doivent \u00eatre proportionnels au nombre de personne appel\u00e9es \u00e0 l\u2019emprunter.<\/p>\n\n\n\n<p>Cette valeur est calcul\u00e9e en fonction d\u2019une largeur type appel\u00e9e&nbsp;unit\u00e9 de passage (UP).<\/p>\n\n\n\n<p>La valeur de l\u2019unit\u00e9 de base est <strong>0,60 m.<\/strong><\/p>\n\n\n\n<p>Attention un d\u00e9gagement qui ne comporte qu\u2019une seule UP sera port\u00e9 \u00e0 <strong>0,90m.<\/strong><\/p>\n\n\n\n<p><strong>Quand le d\u00e9gagement ne comporte qu\u2019une unit\u00e9 de passage la largeur est port\u00e9e de 0,60 m \u00e0 0,90 m<\/strong><\/p>\n\n\n\n<p><strong>Pour 2 UP, <\/strong>&nbsp;<strong>la largeur est port\u00e9e de 1,20 m \u00e0 1,40 m.<\/strong><\/p>\n\n\n\n<p><strong>A partir d&rsquo;une largeur de 3 UP, on applique l&rsquo;unit\u00e9 type de 0,60 m soit 1,80 m.<\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Tableau de calcul des d\u00e9gagements<\/strong><\/h3>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"898\" height=\"734\" src=\"https:\/\/preprod.prepasecu.fr\/wp-content\/uploads\/2021\/01\/ssiap1-tableaucalculdegagements.png\" alt=\"\" class=\"wp-image-848\" srcset=\"https:\/\/prepasecu.fr\/wp-content\/uploads\/2021\/01\/ssiap1-tableaucalculdegagements.png 898w, https:\/\/prepasecu.fr\/wp-content\/uploads\/2021\/01\/ssiap1-tableaucalculdegagements-300x245.png 300w, https:\/\/prepasecu.fr\/wp-content\/uploads\/2021\/01\/ssiap1-tableaucalculdegagements-768x628.png 768w\" sizes=\"(max-width: 898px) 100vw, 898px\" \/><figcaption class=\"wp-element-caption\">Tableau de calcul des d\u00e9gagements<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Balisage<\/h3>\n\n\n\n<p><strong>Les Blocs Autonomes d\u2019Eclairage de S\u00e9curit\u00e9 BAES <\/strong>: ils assurent le balisage des d\u00e9gagements et indiquent les sorties de secours. Ils fonctionnent m\u00eame en cas de coupure du courant et fournissent suffisamment de lumi\u00e8re pour se diriger en cas d\u2019\u00e9vacuation.<\/p>\n\n\n\n<p><strong>Les panneaux d\u2019\u00e9vacuation :<\/strong> Ils sont g\u00e9n\u00e9ralement de couleur blanche sur fond vert et indiquent les directions \u00e0 suivre et les sorties de secours.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Les portes<\/strong><\/h3>\n\n\n\n<p><strong>Les portes coupe-feu <\/strong>: permettent de compartimenter les locaux et de limiter la propagation du feu. Elles sont imperm\u00e9ables \u00e0 la chaleur, aux flammes et aux gaz inflammables pendant une p\u00e9riode normalis\u00e9e. L\u2019ensemble compos\u00e9 du dormant et du vantail s\u2019appelle bloc-porte.<\/p>\n\n\n\n<p><strong>La largeur de passage <\/strong>offerte par une prote est au moins \u00e9gale \u00e0 l\u2019une de celle d\u00e9finie au paragraphe concernant l\u2019unit\u00e9 de passage avec une tol\u00e9rance de 5%<\/p>\n\n\n\n<p><strong>Les portes en va-et-vient <\/strong>comportent une partie vitr\u00e9e \u00e0 hauteur de vue.<\/p>\n\n\n\n<p><strong>Les vitrages <\/strong>des portes sont transparents.<\/p>\n\n\n\n<p><strong>Les portes <\/strong>desservant des locaux de plus de<strong> 50 personnes doivent s\u2019ouvrir dans le sens de la sortie.<\/strong><\/p>\n\n\n\n<p>Les portes doivent s\u2019ouvrir dans le sens de la sortie afin de garantir la fluidit\u00e9 de l\u2019\u00e9vacuation. Il en va de m\u00eame pour les portes d\u2019escalier.<\/p>\n\n\n\n<p>Pour la m\u00eame raison, elles ne doivent pas faire saillie dans le d\u00e9gagement.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Les espaces d\u2019attentes s\u00e9curis\u00e9s<\/h3>\n\n\n\n<p>Ils doivent r\u00e9pondre \u00e0 des caract\u00e9ristiques particuli\u00e8res (CO 59).<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>2 espaces d\u2019attente par niveau.<\/li>\n\n\n\n<li>\u00catre implant\u00e9 \u00e0 proximit\u00e9 d\u2019un escalier consid\u00e9r\u00e9 comme d\u00e9gagement normal.<\/li>\n\n\n\n<li>Distance maximale pour l\u2019atteindre 50m ou 30m s\u2019il n\u2019y a qu\u2019une seule sortie.<\/li>\n\n\n\n<li>Capacit\u00e9 d\u2019accueil minimum deux personnes.<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">L\u2019\u00e9vacuation<\/h3>\n\n\n\n<p><strong>L\u2019\u00e9vacuation est l\u2019objectif essentiel <\/strong>de la s\u00e9curit\u00e9 des personnes. Son but et de mettre tous les occupants d\u2019un locale ou d\u2019un b\u00e2timent \u00e0 l\u2019abri d\u2019un quelconque danger imminent, en les dirigeant vers une zone de s\u00e9curit\u00e9 qui sera souvent \u00e0 l\u2019ext\u00e9rieur.<\/p>\n\n\n\n<p>En principe <strong>l\u2019alarme g\u00e9n\u00e9rale <\/strong>doit \u00eatre donn\u00e9e par <strong>b\u00e2timent.<\/strong><\/p>\n\n\n\n<p><strong>Responsabilit\u00e9 de l\u2019exploitant <\/strong>: l\u2019exploitant est responsable de la s\u00e9curit\u00e9 des personnes admises dans son \u00e9tablissement, pour cela il doit respecter les dispositions r\u00e8glementaires.<\/p>\n\n\n\n<p>L\u2019exploitant organise la s\u00e9curit\u00e9, il doit pr\u00e9voir l\u2019\u00e9vacuation d\u2019urgence de son \u00e9tablissement.<\/p>\n\n\n\n<p>Les exercices ont pour but : <\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>De sensibiliser les personnels \u00e0 la s\u00e9curit\u00e9<\/li>\n\n\n\n<li>De v\u00e9rifier l\u2019audibilit\u00e9 de l\u2019alarme<\/li>\n\n\n\n<li>De reconnaitre les cheminements<\/li>\n\n\n\n<li>De tester la validit\u00e9 des consignes<\/li>\n\n\n\n<li>De r\u00e9duire le temps d\u2019\u00e9vacuation<\/li>\n\n\n\n<li>D\u2019am\u00e9liorer l\u2019organisation de la s\u00e9curit\u00e9<\/li>\n<\/ul>\n\n\n\n<p><strong>Les occupants de l\u2019\u00e9tablissement <\/strong>doivent \u00eatre conscients, par le biais des consignes affich\u00e9es ainsi que par l\u2019intervention des agents de pr\u00e9vention, que l\u2019audition du syst\u00e8me d\u2019alarme correspond \u00e0 l\u2019ordre d\u2019\u00e9vacuation.<\/p>\n\n\n\n<p>Il est i<strong>mportant <\/strong>d\u2019informer sur les <strong>itin\u00e9raires<\/strong> et les <strong>points de rassemblement<\/strong>.<\/p>\n\n\n\n<p><strong>Le responsable d\u2019\u00e9vacuation <\/strong>: un responsable qui s\u2019assure que les consignes sont toujours actualis\u00e9es et visibles. C\u2019est lui qui donne l\u2019ordre d\u2019\u00e9vacuer.<\/p>\n\n\n\n<p><strong>Le guide-fil <\/strong>: guide les occupants vers la meilleure sortie et comptabilise les personnes \u00e9vacu\u00e9es au point de rassemblement.<\/p>\n\n\n\n<p><strong>Le serre-file <\/strong>: il v\u00e9rifie dans l\u2019ensemble des locaux qu\u2019il ne reste personne. Il ferme toutes les portes et les fen\u00eatres. Il cl\u00f4t la marche afin d\u2019\u00e9viter tout retour d\u2019une personne en arri\u00e8re.<\/p>\n\n\n\n<p>L\u2019affichage des consignes g\u00e9n\u00e9rales, particuli\u00e8res et sp\u00e9ciales, des plans d\u2019\u00e9vacuation et d\u2019intervention, leur mise \u00e0 jour r\u00e9guli\u00e8re ainsi que la r\u00e9alisation d\u2019exercices sont le t\u00e9moignage de la volont\u00e9 des responsables d\u2019\u00e9tablissements d\u2019assurer la s\u00e9curit\u00e9 tant du public que de leur personnel.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">R\u00f4le de l\u2019agent de s\u00e9curit\u00e9 incendie<\/h3>\n\n\n\n<p><strong>Au quotidien, porter une attention particuli\u00e8re :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&nbsp;Au d\u00e9verrouillage des portes et issues pendant la pr\u00e9sence du public<\/li>\n\n\n\n<li>A l\u2019absence d\u2019encombrement dans les circulations<\/li>\n\n\n\n<li>A l\u2019absence d\u2019encombrement int\u00e9rieur et ext\u00e9rieur des portes, portes coupe-feu, issues de secours, escaliers, etc\u2026<\/li>\n\n\n\n<li>Au bon fonctionnement du balisage<\/li>\n<\/ul>\n\n\n\n<p><strong>En cas de sinistre, il encadre l\u2019\u00e9vacuation :<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>&nbsp;cesser et faire cesser toute activit\u00e9<\/li>\n\n\n\n<li>\u00e9teindre toutes sources d\u2019activation<\/li>\n\n\n\n<li>s\u2019assurer de l\u2019isolement du sinistre (compartimentage)<\/li>\n\n\n\n<li>guider le public vers le point de rassemblement<\/li>\n\n\n\n<li>\u00ab ratisser \u00bb l\u2019\u00e9tablissement pour s\u2019assurer que personne ne reste en arri\u00e8re (attention au cul-de-sac)<\/li>\n<\/ul>\n\n\n\n<p><strong>Une fois l\u2019\u00e9vacuation effectu\u00e9e, informer syst\u00e9matiquement le P.C de tout \u00e9l\u00e9ment important : personne bless\u00e9e, personne manquante, etc\u2026<\/strong><\/p>\n\n\n\n <\/div><div id=\"poool-widget\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Ces cours peuvent aussi vous int\u00e9resser \ud83d\udc47<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/prepasecu.fr\/ssiap-1\/cours\/la-securite-incendie\/cloisonnement-des-risques\/\" title=\"Cloisonnement des risques\">Cloisonnement des risques<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/preprod.prepasecu.fr\/ssiap-1\/cours\/la-securite-incendie\/evacuation-des-occupants\/\" title=\"\u00c9vacuation du public et des occupants\"><\/a><a href=\"https:\/\/preprod.prepasecu.fr\/ssiap-1\/cours\/la-securite-incendie\/desenfumage\/\" title=\"Le d\u00e9senfumage\"><\/a><a href=\"https:\/\/prepasecu.fr\/ssiap-1\/cours\/la-securite-incendie\/desenfumage\/\" title=\"\">D\u00e9senfumage<\/a><\/li>\n<\/ul>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>D\u00e9finition D\u00e9gagement : toute partie de la construction permettant le cheminement d\u2019\u00e9vacuation des occupants : porte, sortie, issue, circulation horizontale, zone de circulation, escalier, couloir, rampe, etc\u2026 Les d\u00e9gagements r\u00e9glementaires : D\u00e9gagement normal : d\u00e9gagement comptant dans le nombre minimal de d\u00e9gagement impos\u00e9s. Il peut \u00eatre utilis\u00e9 par le public lors de l\u2019exploitation de l\u2019\u00e9tablissement. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_uag_custom_page_level_css":"","_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[33,64,3],"tags":[],"class_list":{"0":"post-844","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-cours-ssiap-1","7":"category-la-securite-incendie","8":"category-ssiap-1","9":"entry"},"aioseo_notices":[],"featured_image_src":null,"featured_image_src_square":null,"author_info":{"display_name":"Matthis","author_link":"https:\/\/prepasecu.fr\/?author=1"},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"sidebar-featured":false,"genesis-singular-images":false,"gb-block-post-grid-landscape":false,"gb-block-post-grid-square":false,"yarpp-thumbnail":false},"uagb_author_info":{"display_name":"Matthis","author_link":"https:\/\/prepasecu.fr\/?author=1"},"uagb_comment_info":0,"uagb_excerpt":"D\u00e9finition D\u00e9gagement : toute partie de la construction permettant le cheminement d\u2019\u00e9vacuation des occupants : porte, sortie, issue, circulation horizontale, zone de circulation, escalier, couloir, rampe, etc\u2026 Les d\u00e9gagements r\u00e9glementaires : D\u00e9gagement normal : d\u00e9gagement comptant dans le nombre minimal de d\u00e9gagement impos\u00e9s. Il peut \u00eatre utilis\u00e9 par le public lors de l\u2019exploitation de l\u2019\u00e9tablissement.\u2026","_links":{"self":[{"href":"https:\/\/prepasecu.fr\/index.php?rest_route=\/wp\/v2\/posts\/844"}],"collection":[{"href":"https:\/\/prepasecu.fr\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/prepasecu.fr\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/prepasecu.fr\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/prepasecu.fr\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=844"}],"version-history":[{"count":0,"href":"https:\/\/prepasecu.fr\/index.php?rest_route=\/wp\/v2\/posts\/844\/revisions"}],"wp:attachment":[{"href":"https:\/\/prepasecu.fr\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=844"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/prepasecu.fr\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=844"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/prepasecu.fr\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=844"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}